{"id":7739,"date":"2026-03-17T20:30:00","date_gmt":"2026-03-17T12:30:00","guid":{"rendered":"https:\/\/jinzho.com\/?p=7739"},"modified":"2026-04-20T12:09:50","modified_gmt":"2026-04-20T04:09:50","slug":"comment-tester-un-element-chauffant-de-seche-linge-general-electric","status":"publish","type":"post","link":"https:\/\/jinzho.com\/fr\/how-to-test-a-general-electric-dryer-heating-element\/","title":{"rendered":"Comment Tester un \u00c9l\u00e9ment Chauffant de S\u00e8che-Linge General Electric"},"content":{"rendered":"<div class=\"wp-ge-dryer-test\" style=\"width:100%;max-width:100%;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,Arial,'Helvetica Neue',Helvetica,sans-serif;color:#111;line-height:1.82;\">\n  <style>\n    .wp-ge-dryer-test{font-size:16px}\n    \/* No h1-h5 tags; use styled divs *\/\n    .t1{font-size:34px;font-weight:900;line-height:1.15;margin:0}\n    .t2{font-size:24px;font-weight:900;line-height:1.25;margin:22px 0 8px}\n    .t3{font-size:19px;font-weight:900;line-height:1.35;margin:18px 0 6px}\n    .t4{font-size:16px;font-weight:900;line-height:1.45;margin:14px 0 6px}\n    .t5{font-size:13px;font-weight:900;letter-spacing:.02em;text-transform:uppercase;margin:12px 0 6px;color:#222}\n\n    p{margin:12px 0 0}\n    ul,ol{margin:10px 0 0;padding-left:20px}\n    li{margin:6px 0}\n    a{color:#0b57d0;text-decoration:underline}\n\n    .box{border:1px solid #eee;border-radius:14px;padding:14px 16px;background:#fff;margin:14px 0}\n    .note{background:#fff8e6;border-color:#ffe3a3}\n    .warn{background:#fff5f5;border-color:#fed7d7}\n    .ok{background:#f7fffb;border-color:#c6f6d5}\n    .toc{background:#fcfcff;border-color:#e9ecff}\n\n    .meta{display:flex;flex-wrap:wrap;gap:8px;margin:12px 0 0}\n    .chip{display:inline-block;padding:4px 10px;border-radius:999px;font-size:12px;border:1px solid #e7e7e7;background:#fafafa}\n\n    .grid{display:grid;grid-template-columns:1fr;gap:12px}\n    @media (min-width:900px){.grid{grid-template-columns:1fr 1fr}}\n\n    .tableWrap{overflow:auto;border:1px solid #eee;border-radius:14px;background:#fff;margin:12px 0}\n    table{border-collapse:collapse;min-width:980px;width:100%}\n    th,td{border-bottom:1px solid #f0f0f0;padding:10px 12px;vertical-align:top}\n    th{background:#fafafa;text-align:left;font-size:12px;letter-spacing:.02em;text-transform:uppercase}\n    .caption{font-size:13px;color:#444;margin:8px 2px 0}\n\n    .hr{height:1px;background:#eee;margin:18px 0}\n    .small{font-size:13px;color:#444}\n    .kbd{font-family:ui-monospace,SFMono-Regular,Menlo,Monaco,Consolas,'Liberation Mono','Courier New',monospace;font-size:13px;background:#f6f6f6;border:1px solid #ececec;border-radius:8px;padding:1px 6px}\n    .callout{border-left:4px solid #111;padding:10px 12px;background:#fafafa;border-radius:12px;margin:12px 0 0}\n\n    .step{display:flex;gap:10px;align-items:flex-start;margin:10px 0}\n    .stepNo{flex:0 0 auto;width:28px;height:28px;border-radius:999px;background:#111;color:#fff;display:flex;align-items:center;justify-content:center;font-weight:900;font-size:13px;margin-top:2px}\n    .stepBody{flex:1}\n  <\/style>\n\n  <div class=\"t1\">Comment Tester un \u00c9l\u00e9ment Chauffant de S\u00e8che-Linge General Electric<\/div>\n  <p class=\"small\">Page de cluster ? ~2006 mots ? Global ? 8 FAQ ? Diagnostics bas\u00e9s sur un multim\u00e8tre<\/p>\n  <div class=\"meta\" aria-label=\"article-meta\">\n    <span class=\"chip\">Continuit\u00e9 + ohms<\/span>\n    <span class=\"chip\">Priorit\u00e9 au flux d'air<\/span>\n    <span class=\"chip\">V\u00e9rification de court-circuit \u00e0 la masse<\/span>\n    <span class=\"chip\">\u00c9viter les \u00e9checs r\u00e9p\u00e9t\u00e9s<\/span>\n  <\/div>\n\n  <!-- Per requirement: do NOT repeat the H1 title text in the body. Start with intro. -->\n  <div class=\"box note\">\n    <div class=\"t3\" style=\"margin-top:0\">Ce que ce test peut (et ne peut pas) prouver<\/div>\n    <p style=\"margin-top:0\">\n      Test d\u2019un s\u00e8che-linge GE <a href=\"https:\/\/jinzho.com\/general-electric-dryer-heating-element-replacement-walkthrough\/\"  data-wpil-monitor-id=\"1766\">\u00e9l\u00e9ment chauffant<\/a> avec un multim\u00e8tre peut confirmer si l\u2019\u00e9l\u00e9ment est \u00e9lectriquement continu (probablement utilisable) ou ouvert (d\u00e9faillant). <a href=\"https:\/\/jinzho.com\/how-to-test-a-whirlpool-heating-element-for-a-dryer\/\"  data-wpil-monitor-id=\"1933\">la production de chaleur en fonctionnement \u2013 les fusibles thermiques<\/a>, les thermostats, les points chauds de c\u00e2blage et un flux d\u2019air restreint peuvent encore emp\u00eacher le chauffage.\n    <\/p>\n    <p class=\"small\">\n      Contexte technique : TUTCO explique qu\u2019un \u00e9l\u00e9ment chauffant est un ensemble (alliage conducteur + cadre isolant + bornes) et que l\u2019environnement et les conditions de fonctionnement affectent sa dur\u00e9e de vie et ses performances.\n      <a href=\"https:\/\/tutco.com\/conductive\/heating-elements\" target=\"_blank\" rel=\"noopener nofollow\">https:\/\/tutco.com\/conductive\/heating-elements<\/a>\n    <\/p>\n  <\/div>\n\n  <div class=\"box toc\" aria-label=\"table des mati\u00e8res\">\n    <div class=\"t3\" style=\"margin-top:0\">Table des mati\u00e8res<\/div>\n    <ul>\n      <li><a href=\"#symptoms\">Sympt\u00f4mes justifiant un test<\/a><\/li>\n      <li><a href=\"#tools\">Outils et configuration<\/a><\/li>\n      <li><a href=\"#safety\">Liste de contr\u00f4le de s\u00e9curit\u00e9 (obligatoire)<\/a><\/li>\n      <li><a href=\"#airflow\">V\u00e9rification du flux d\u2019air en premier (\u00e9vite un diagnostic erron\u00e9)<\/a><\/li>\n      <li><a href=\"#access\">Acc\u00e8s \u00e0 l\u2019\u00e9l\u00e9ment (configurations GE courantes)<\/a><\/li>\n      <li><a href=\"#tests\">Tests au multim\u00e8tre : continuit\u00e9, r\u00e9sistance et court-circuit au ch\u00e2ssis<\/a><\/li>\n      <li><a href=\"#interpret\">Interpr\u00e9tation des r\u00e9sultats<\/a><\/li>\n      <li><a href=\"#next\">Si l'\u00e9l\u00e9ment est bon : quoi tester ensuite<\/a><\/li>\n      <li><a href=\"#faq\">FAQ (8)<\/a><\/li>\n      <li><a href=\"#sources\">R\u00e9f\u00e9rences et liens internes obligatoires<\/a><\/li>\n    <\/ul>\n  <\/div>\n\n  <div id=\"symptoms\" class=\"t2\">Sympt\u00f4mes justifiant un test<\/div>\n  <div class=\"tableWrap\" aria-label=\"tableau-sympt\u00f4mes\">\n    <table>\n      <thead>\n        <tr>\n          <th>Sympt\u00f4me<\/th>\n          <th>Ce que cela indique souvent<\/th>\n          <th>Premi\u00e8re v\u00e9rification rapide<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Le s\u00e8che-linge tourne, pas de chaleur<\/td>\n          <td>\u00c9l\u00e9ment ouvert, fusible thermique ouvert, ou absence d\u2019une phase 240V<\/td>\n          <td>\u00c9tat du disjoncteur + flux d\u2019air \u00e0 l\u2019\u00e9vacuation ext\u00e9rieure<\/td>\n        <\/tr>\n        <tr>\n          <td>Chauffe puis s\u2019arr\u00eate<\/td>\n          <td>Condition de surchauffe ou comportement de cyclage\/limite haute<\/td>\n          <td>Restriction de ventilation \/ accumulation de charpie<\/td>\n        <\/tr>\n        <tr>\n          <td>Temps de s\u00e9chage longs<\/td>\n          <td>Faible flux d\u2019air, chaleur partielle, ou probl\u00e8mes de commande<\/td>\n          <td>R\u00e9sistance du clapet d\u2019\u00e9vacuation ext\u00e9rieur<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"caption\">Tableau 1 \u2013 Le test est le plus utile apr\u00e8s avoir pris en compte le flux d\u2019air et l\u2019alimentation \u00e9lectrique.<\/p>\n\n  <div id=\"tools\" class=\"t2\">Outils et configuration<\/div>\n  <div class=\"grid\">\n    <div class=\"box\">\n      <div class=\"t3\" style=\"margin-top:0\">Outillage<\/div>\n      <ul>\n        <li>Multim\u00e8tre (continuit\u00e9 + ohms)<\/li>\n        <li>Jeu de douilles\/tournevis<\/li>\n        <li>Pince \u00e0 bec effil\u00e9 (connecteurs \u00e0 fourche)<\/li>\n        <li>Aspirateur et brosse \u00e0 charpie<\/li>\n      <\/ul>\n    <\/div>\n    <div class=\"box\">\n      <div class=\"t3\" style=\"margin-top:0\">Auto-v\u00e9rification rapide du multim\u00e8tre<\/div>\n      <ul>\n        <li>Toucher les pointes ensemble : un bip de continuit\u00e9 doit retentir.<\/li>\n        <li>En mode ohms, les pointes ensemble doivent afficher une valeur proche de 0 \u03a9. .<\/li>\n      <\/ul>\n      <p class=\"small\">\n        Conseil : Si votre multim\u00e8tre est \u00e0 gamme automatique, il g\u00e9rera la s\u00e9lection d\u2019\u00e9chelle automatiquement.\n      <\/p>\n    <\/div>\n  <\/div>\n\n  <div id=\"safety\" class=\"t2\">Liste de contr\u00f4le de s\u00e9curit\u00e9 (obligatoire)<\/div>\n  <div class=\"box warn\">\n    <div class=\"t3\" style=\"margin-top:0\">Avant tout retrait de panneau<\/div>\n    <ul>\n      <li>D\u00e9brancher le s\u00e8che-linge (ou couper le disjoncteur pour les installations c\u00e2bl\u00e9es).<\/li>\n      <li>Confirmer que le s\u00e8che-linge ne peut pas d\u00e9marrer (les commandes doivent \u00eatre hors tension).<\/li>\n      <li>Laisser refroidir la zone du chauffage.<\/li>\n      <li>Porter des gants \u2013 les bords en t\u00f4le peuvent couper.<\/li>\n    <\/ul>\n    <p class=\"small\">\n      Exemple de principe de s\u00e9curit\u00e9 : les instructions de remplacement de l\u2019\u00e9l\u00e9ment chauffant de Whirlpool mettent en garde contre le r\u00e9tablissement de l\u2019alimentation avant que le syst\u00e8me ne soit pr\u00eat (dans leur cas, le r\u00e9servoir doit \u00eatre plein pour \u00e9viter un \u00ab grillage \u00e0 sec \u00bb),.\n      <a href=\"https:\/\/www.whirlpoolwaterheaters.com\/support\/help\/element-was-out-of-range\/24\" target=\"_blank\" rel=\"noopener nofollow\">R\u00e9f\u00e9rence<\/a>.\n    <\/p>\n  <\/div>\n\n  <div id=\"airflow\" class=\"t2\">V\u00e9rification du flux d\u2019air en premier (\u00e9vite un diagnostic erron\u00e9)<\/div>\n  <div class=\"box ok\">\n    <div class=\"t3\" style=\"margin-top:0\">Pourquoi le flux d\u2019air passe en premier<\/div>\n    <p style=\"margin-top:0\">\n      Les chauffages de s\u00e8che-linge sont des chauffages \u00ab \u00e0 air de process \u00bb : ils doivent transf\u00e9rer la chaleur dans l\u2019air en mouvement. Un flux d\u2019air restreint provoque une surchauffe et des coupures de s\u00e9curit\u00e9, et peut r\u00e9duire la dur\u00e9e de vie de l\u2019\u00e9l\u00e9ment.\n      <a href=\"https:\/\/tutco.com\/conductive\/heating-elements\" target=\"_blank\" rel=\"noopener nofollow\">R\u00e9f\u00e9rence<\/a>.\n    <\/p>\n    <ul>\n      <li>V\u00e9rifier un flux d\u2019air fort \u00e0 la sortie d\u2019\u00e9vacuation ext\u00e9rieure.<\/li>\n      <li>Inspecter et remplacer les conduits flexibles \u00e9cras\u00e9s ou pli\u00e9s.<\/li>\n      <li>Nettoyer l\u2019accumulation de charpie dans le conduit d\u2019un bout \u00e0 l\u2019autre.<\/li>\n    <\/ul>\n  <\/div>\n\n  <div id=\"access\" class=\"t2\">Acc\u00e8s \u00e0 l\u2019\u00e9l\u00e9ment (configurations GE courantes)<\/div>\n  <div class=\"box note\">\n    <div class=\"t3\" style=\"margin-top:0\">Diff\u00e9rences entre mod\u00e8les<\/div>\n    <p style=\"margin-top:0\">\n      Les conceptions des s\u00e8che-linge GE varient. De nombreux appareils offrent un acc\u00e8s arri\u00e8re au bo\u00eetier du chauffage ; d\u2019autres n\u00e9cessitent un acc\u00e8s avant ou inf\u00e9rieur.\n    <\/p>\n  <\/div>\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">Liste de contr\u00f4le d\u2019acc\u00e8s<\/div>\n    <ol>\n      <li>D\u00e9connecter le tuyau d\u2019\u00e9vacuation.<\/li>\n      <li>Retirer le panneau de service appropri\u00e9.<\/li>\n      <li>Localiser le bo\u00eetier du chauffage et les deux bornes principales de l\u2019\u00e9l\u00e9ment.<\/li>\n      <li>Photographier le c\u00e2blage avant de d\u00e9connecter.<\/li>\n    <\/ol>\n  <\/div>\n\n  <div id=\"tests\" class=\"t2\">Tests au multim\u00e8tre : continuit\u00e9, r\u00e9sistance et court-circuit au ch\u00e2ssis<\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">Test 1 \u2013 Continuit\u00e9 aux bornes de l\u2019\u00e9l\u00e9ment<\/div>\n    <div class=\"step\">\n      <div class=\"stepNo\">1<\/div>\n      <div class=\"stepBody\">\n        <div class=\"t4\" style=\"margin:0\">Isolez l'\u00e9l\u00e9ment<\/div>\n        <p style=\"margin-top:6px\">\n          Retirer au moins un fil de l\u2019\u00e9l\u00e9ment pour ne pas mesurer \u00e0 travers le circuit.\n        <\/p>\n      <\/div>\n    <\/div>\n    <div class=\"step\">\n      <div class=\"stepNo\">2<\/div>\n      <div class=\"stepBody\">\n        <div class=\"t4\" style=\"margin:0\">Mettez les pointes de touche sur les bornes (borne \u00e0 borne)<\/div>\n        <p style=\"margin-top:6px\">\n          Placer une pointe sur chaque borne principale. Un bip (ou une r\u00e9sistance non infinie) indique g\u00e9n\u00e9ralement que l\u2019\u00e9l\u00e9ment n\u2019est pas ouvert.\n        <\/p>\n      <\/div>\n    <\/div>\n    <div class=\"callout small\">\n      Rappel de la d\u00e9finition de TUTCO : l\u2019\u00ab \u00e9l\u00e9ment \u00bb inclut les bornes et le cadre isolant \u2013 inspectez donc les bornes pour d\u00e9tecter une surchauffe dans le cadre de la m\u00eame enqu\u00eate de d\u00e9faillance.\n      <a href=\"https:\/\/tutco.com\/conductive\/heating-elements\" target=\"_blank\" rel=\"noopener nofollow\">Source<\/a>.\n    <\/div>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">Test 2 \u2013 R\u00e9sistance (\u03a9) aux bornes de l\u2019\u00e9l\u00e9ment<\/div>\n    <p style=\"margin-top:0\">\n      Passer le multim\u00e8tre en mode ohms et mesurer aux m\u00eames bornes. Un \u00e9l\u00e9ment fonctionnel affiche g\u00e9n\u00e9ralement une valeur de r\u00e9sistance finie.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">Test 3 \u2013 V\u00e9rification de court-circuit au ch\u00e2ssis (fuite \u00e0 la terre)<\/div>\n    <p style=\"margin-top:0\">\n      Placer une pointe sur une borne de l\u2019\u00e9l\u00e9ment et l\u2019autre sur une partie m\u00e9tallique propre du bo\u00eetier\/ch\u00e2ssis du chauffage. R\u00e9p\u00e9ter pour l\u2019autre borne.\n    <\/p>\n    <ul>\n      <li><b>Normal :<\/b> pas de continuit\u00e9 \/ r\u00e9sistance tr\u00e8s \u00e9lev\u00e9e au ch\u00e2ssis.<\/li>\n      <li><b>Mauvais :<\/b> La continuit\u00e9 mesurable vers le ch\u00e2ssis sugg\u00e8re un \u00e9l\u00e9ment en court-circuit ou une isolation\/position endommag\u00e9e.<\/li>\n    <\/ul>\n  <\/div>\n\n  <div id=\"interpret\" class=\"t2\">Interpr\u00e9tation des r\u00e9sultats<\/div>\n  <div class=\"tableWrap\" aria-label=\"tableau-interpr\u00e9tation\">\n    <table>\n      <thead>\n        <tr>\n          <th>Constat<\/th>\n          <th>Signification probable<\/th>\n          <th>\u00c9tape suivante recommand\u00e9e<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <td>Circuit ouvert aux bornes de l'\u00e9l\u00e9ment (OL \/ pas de bip)<\/td>\n          <td>\u00c9l\u00e9ment chauffant d\u00e9faillant<\/td>\n          <td>Remplacer l'\u00e9l\u00e9ment ; traiter les probl\u00e8mes de flux d'air et de bornes pour \u00e9viter une nouvelle rupture<\/td>\n        <\/tr>\n        <tr>\n          <td>R\u00e9sistance finie aux bornes de l'\u00e9l\u00e9ment<\/td>\n          <td>L'\u00e9l\u00e9ment pr\u00e9sente une continuit\u00e9 \u00e9lectrique<\/td>\n          <td>Tester le fusible thermique \/ le thermostat de s\u00e9curit\u00e9 \/ le thermostat cyclique ; inspecter les bornes et l'alimentation<\/td>\n        <\/tr>\n        <tr>\n          <td>Continuit\u00e9 entre une borne et le ch\u00e2ssis<\/td>\n          <td>Court-circuit vers le carter<\/td>\n          <td>Ne pas faire fonctionner ; remplacer l'\u00e9l\u00e9ment et v\u00e9rifier le positionnement\/l'isolation corrects<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"caption\">Tableau 2 : L'\u00e9l\u00e9ment peut sembler bon au test, mais le s\u00e8che-linge peut toujours ne pas chauffer en raison des dispositifs de s\u00e9curit\u00e9 ou de probl\u00e8mes d'alimentation.<\/p>\n\n  <div id=\"next\" class=\"t2\">Si l'\u00e9l\u00e9ment est bon : quoi tester ensuite<\/div>\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">V\u00e9rifications suivantes (causes courantes d'absence de chaleur)<\/div>\n    <ul>\n      <li><b>Fusible thermique \/ coupeur thermique :<\/b> Doit g\u00e9n\u00e9ralement pr\u00e9senter une continuit\u00e9 \u00e0 temp\u00e9rature ambiante ; s'il est ouvert, corriger les probl\u00e8mes de flux d'air.<\/li>\n      <li><b>Thermostat de s\u00e9curit\u00e9 (limiteur) :<\/b> Souvent ferm\u00e9 \u00e0 temp\u00e9rature ambiante (selon le mod\u00e8le) ; s'il est ouvert, rechercher la cause de la surchauffe.<\/li>\n      <li><b>Borne de raccordement et cordon d'alimentation :<\/b> Une surchauffe ou des connexions desserr\u00e9es peuvent r\u00e9duire la puissance du chauffage.<\/li>\n      <li><b>Restriction de l'\u00e9vacuation :<\/b> Peut d\u00e9clencher les coupeurs m\u00eame avec un \u00e9l\u00e9ment en bon \u00e9tat.<\/li>\n    <\/ul>\n    <p class=\"small\">\n      Rigueur de connexion : Les \u00e9tapes de remplacement du chauffage Whirlpool indiquent explicitement : \u00ab Assurez-vous que toutes les connexions de fils sont serr\u00e9es. \u00bb Des connexions l\u00e2ches peuvent cr\u00e9er des points chauds et un chauffage intermittent.\n      <a href=\"https:\/\/www.whirlpoolwaterheaters.com\/support\/help\/element-was-out-of-range\/24\" target=\"_blank\" rel=\"noopener nofollow\">R\u00e9f\u00e9rence<\/a>.\n    <\/p>\n  <\/div>\n\n  <div id=\"faq\" class=\"t2\">FAQ (8)<\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">1) Puis-je tester l'\u00e9l\u00e9ment chauffant sans le retirer ?<\/div>\n    <p style=\"margin-top:0\">\n      G\u00e9n\u00e9ralement oui, \u00e0 condition que les bornes soient accessibles et que vous d\u00e9branchiez au moins un fil pour l'isoler et obtenir une lecture pr\u00e9cise.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">2) Que signifie \u00ab OL \u00bb sur le multim\u00e8tre ?<\/div>\n    <p style=\"margin-top:0\">\n        \u00ab OL \u00bb signifie typiquement boucle ouverte \/ circuit ouvert. Aux bornes de l'\u00e9l\u00e9ment, cela indique g\u00e9n\u00e9ralement une r\u00e9sistance cass\u00e9e (\u00e9l\u00e9ment d\u00e9faillant).\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">3) Pourquoi le tambour tourne-t-il mais ne chauffe-t-il pas ?<\/div>\n    <p style=\"margin-top:0\">\n      Il peut y avoir un \u00e9l\u00e9ment ouvert, un fusible thermique ouvert ou une absence d'alimentation du chauffage (probl\u00e8me sur une phase\/un disjoncteur). Commencez par v\u00e9rifier le flux d'air et l'alimentation.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">4) Si je remplace l'\u00e9l\u00e9ment, dois-je aussi remplacer le fusible ?<\/div>\n    <p style=\"margin-top:0\">\n      Si le fusible thermique est ouvert, il doit \u00eatre remplac\u00e9 pour que la chaleur revienne. Mais le remplacer sans corriger les restrictions de flux d'air conduit souvent \u00e0 une nouvelle d\u00e9faillance.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">5) Qu'est-ce qui provoque des d\u00e9faillances r\u00e9p\u00e9t\u00e9es de l'\u00e9l\u00e9ment ?<\/div>\n    <p style=\"margin-top:0\">\n      Un flux d'air restreint et des bornes surchauff\u00e9es sont les causes les plus courantes. TUTCO note que la dur\u00e9e de vie du chauffage est limit\u00e9e par l'oxydation, la d\u00e9formation et les contraintes cycliques ; la surchauffe acc\u00e9l\u00e8re ces ph\u00e9nom\u00e8nes.\n      <a href=\"https:\/\/tutco.com\/conductive\/heating-elements\" target=\"_blank\" rel=\"noopener nofollow\">R\u00e9f\u00e9rence<\/a>.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">6) Dois-je tester le court-circuit vers le ch\u00e2ssis ?<\/div>\n    <p style=\"margin-top:0\">\n      C'est un contr\u00f4le de s\u00e9curit\u00e9 important. Un \u00e9l\u00e9ment en court-circuit peut faire disjoncter ou cr\u00e9er des conditions dangereuses m\u00eame s'il pr\u00e9sente encore une certaine continuit\u00e9.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">7) Que faire si les bornes semblent br\u00fbl\u00e9es ?<\/div>\n    <p style=\"margin-top:0\">\n      Remplacer les bornes. Des connecteurs br\u00fbl\u00e9s ou desserr\u00e9s peuvent surchauffer, endommager le nouvel \u00e9l\u00e9ment ou provoquer un chauffage intermittent.\n    <\/p>\n  <\/div>\n\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">8) Que dois-je v\u00e9rifier avant d'acheter un \u00e9l\u00e9ment de remplacement ?<\/div>\n    <p style=\"margin-top:0\">\n      Faire correspondre le num\u00e9ro de mod\u00e8le exact et la g\u00e9om\u00e9trie de la pi\u00e8ce. Suivre la m\u00eame d\u00e9marche de \u00ab v\u00e9rification des caract\u00e9ristiques\/sp\u00e9cifications \u00bb que Whirlpool recommande pour les remplacements de chauffage (tension\/puissance) et assurer des connexions serr\u00e9es lors du remontage.\n      <a href=\"https:\/\/www.whirlpoolwaterheaters.com\/support\/help\/element-was-out-of-range\/24\" target=\"_blank\" rel=\"noopener nofollow\">Source<\/a>.\n    <\/p>\n  <\/div>\n\n  <div id=\"sources\" class=\"t2\">R\u00e9f\u00e9rences et liens internes obligatoires<\/div>\n  <div class=\"box\">\n    <div class=\"t3\" style=\"margin-top:0\">Sources principales utilis\u00e9es<\/div>\n    <ul>\n      <li>\n        TUTCO \u2013 d\u00e9finition, types et facteurs de dur\u00e9e de vie des chauffages :\n        <a href=\"https:\/\/tutco.com\/conductive\/heating-elements\" target=\"_blank\" rel=\"noopener nofollow\">https:\/\/tutco.com\/conductive\/heating-elements<\/a>\n      <\/li>\n      <li>\n        Whirlpool \u2013 \u00ab Remplacer l'\u00e9l\u00e9ment chauffant \u00bb (v\u00e9rifier l'\u00e9l\u00e9ment correct ; connexions serr\u00e9es ; mise sous tension s\u00e9curis\u00e9e) :\n        <a href=\"https:\/\/www.whirlpoolwaterheaters.com\/support\/help\/element-was-out-of-range\/24\" target=\"_blank\" rel=\"noopener nofollow\">https:\/\/www.whirlpoolwaterheaters.com\/support\/help\/element-was-out-of-range\/24<\/a>\n      <\/li>\n      <li>\n        Hudson Reed \u2013 exemple de liste de chauffages ax\u00e9e sur les sp\u00e9cifications (hors s\u00e8che-linge) :\n        <a href=\"https:\/\/usa.hudsonreed.com\/1000-plug-in-watt-electric-heating-element-76309\" target=\"_blank\" rel=\"noopener nofollow\">https:\/\/usa.hudsonreed.com\/1000-plug-in-watt-electric-heating-element-76309<\/a>\n      <\/li>\n    <\/ul>\n\n    <div class=\"hr\"><\/div>\n\n    <div class=\"t3\" style=\"margin-top:0\">Ancres internes requises<\/div>\n    <ul>\n      <li><a href=\"https:\/\/jinzho.com\/product-category\/heating-element\/\" target=\"_blank\" rel=\"noopener\">\u00c9l\u00e9ment chauffant<\/a><\/li>\n      <li><a href=\"https:\/\/jinzho.com\/\" target=\"_blank\" rel=\"noopener\">Fabricant d'\u00e9l\u00e9ments chauffants<\/a><\/li>\n      <li><a href=\"https:\/\/jinzho.com\/about\/\" target=\"_blank\" rel=\"noopener\">Usine d'\u00e9l\u00e9ments chauffants<\/a><\/li>\n      <li><a href=\"https:\/\/jinzho.com\/product-category\/die-casting-heating-solutions\/\" target=\"_blank\" rel=\"noopener\">Solutions de chauffage pour la coul\u00e9e sous pression<\/a><\/li>\n    <\/ul>\n\n    <div class=\"t4\">Pages de cat\u00e9gorie JINZHO associ\u00e9es (contexte)<\/div>\n    <ul class=\"small\">\n      <li><a href=\"https:\/\/jinzho.com\/product-category\/heating-element\/heating-tubes\/\" target=\"_blank\" rel=\"noopener\">Tubes de chauffage<\/a><\/li>\n      <li><a href=\"https:\/\/jinzho.com\/product-category\/heating-element\/heating-plate\/\" target=\"_blank\" rel=\"noopener\">Plaque chauffante<\/a><\/li>\n      <li><a href=\"https:\/\/jinzho.com\/product-category\/heating-element\/heating-film\/\" target=\"_blank\" rel=\"noopener\">Film chauffant<\/a><\/li>\n      <li><a href=\"https:\/\/jinzho.com\/product-category\/electric-heater-parts\/electric-boiler-heater\/\" target=\"_blank\" rel=\"noopener\">Chaudi\u00e8re \u00e9lectrique<\/a><\/li>\n    <\/ul>\n\n    <p class=\"small\" style=\"margin-top:10px\">\n      Clause de non-responsabilit\u00e9 : Ceci est un guide de diagnostic g\u00e9n\u00e9ral pour les s\u00e8che-linge \u00e9lectriques GE. Les conceptions varient selon les mod\u00e8les. Suivez la documentation de service sp\u00e9cifique au mod\u00e8le et les pratiques de s\u00e9curit\u00e9 \u00e9lectrique.\n    <\/p>\n  <\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Tester l'\u00e9l\u00e9ment chauffant d'un s\u00e8che-linge GE avec un multim\u00e8tre permet de confirmer rapidement si la r\u00e9sistance chauffante est coup\u00e9e, en court-circuit ou fonctionne normalement. Ce guide pr\u00e9sente la m\u00e9thode la plus s\u00fbre pour acc\u00e9der \u00e0 l'\u00e9l\u00e9ment, o\u00f9 placer les pointes de mesure du multim\u00e8tre et comment interpr\u00e9ter les lectures avant de commander une pi\u00e8ce de rechange.<\/p>","protected":false},"author":2,"featured_media":6638,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-7739","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electric-heating-knowledge"],"_links":{"self":[{"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/posts\/7739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/comments?post=7739"}],"version-history":[{"count":3,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/posts\/7739\/revisions"}],"predecessor-version":[{"id":8858,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/posts\/7739\/revisions\/8858"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/media\/6638"}],"wp:attachment":[{"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/media?parent=7739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/categories?post=7739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jinzho.com\/fr\/wp-json\/wp\/v2\/tags?post=7739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}